10. Drive and Auxiliary Pump
1. Lower the lift arms to the ground.
2. Turn the ignition switch to the OFF position.
3. Release any residual pressure from the hydraulic
circuits.
4. Drain the hydraulic oil. Refer to chapter 13,
hydraulic fluid and filter change.
5. Remove the seat. Refer to chapter 6. Seat
Removal.
Figure 10-1
6. View with seat removed.
Figure 10-2
7. Remove the access cover beneath the seat as
shown.
Figure 10-3
8. Remove the bolts from the flange halves securing
the inlet hose/tube to the auxiliary pump. Remove
the flange halves and lay the hose/tube aside.
Figure 10-4
9. Remove the bolts from the flange halves securing
the implement outlet hose/tube to the auxiliary
pump. Remove the flange pieces and lay the
hose/tube aside..
Figure 10-5
10. Disconnect the tube from the fitting in the charge
pressure outlet of the aux pump.