Terex R160T Service & Repair Manual page 51

Hide thumbs Also See for R160T:
Table of Contents

Advertisement

Compact Track Loader
10. Drive and Auxiliary Pump
A
Figure 10-8
8. Disconnect the 5 pilot hoses (A) from the fittings
on the left side (and top center) of the drive pump.
Note: Directional references are to be understood from
the perspective of an operator, seated inside the cab.
9. Disconnect hose B from the fitting on block C.
10. Disconnect and remove tubes D and E from the
machine.
11. Disconnect drive hoses F from the drive pump and
move aside for pump removal clearance.
12. Disconnect case drain hose G from the fitting on
the bottom of the pump.
E
F
G
Figure 10-9
13. Support the weight of the pump from the top side
with a suitable lifting device and straps, then
loosen and remove the two bolts securing the
pump to the engine adapter plate (fig. 10-8, 10-9).
14. Once the bolts have been removed, slide the
pump forward slightly out of the engine, then
gently lower it through the opening below to
remove.