Datamax Prodigy Plus Operator's Manual page 118

Table of Contents

Advertisement

RIBBON ON/OFF
SWITCH:
DARKNESS POT:
28
The POWER indicator light is lit when power is
available and the rear POWER switch is
activated.
This indicator is lit when no media edge and/or no
ribbon motion is detected; a fault condition.
The PAUSE indicator will turn on if any of the
following occurs:
• The PAUSE switch is pressed.
• A print job is canceled with the CANCEL switch.
This switch temporarily interrupts the printing
process illuminating the Pause LED. A second press
allows printing to resume and extinguishes the LED.
When pressed the paper will advance to the first print
position of the next label. In addition this button is
used to clear fault conditions indicated by the Ribbon
Media LED.
Interrupts and deletes the active print job.
For direct thermal printing, (no ribbon), slide the
switch to the "off " position. For thermal transfer
printing, (ribbon installed), slide the switch to the
"on" position. This Switch is not present on the
LCD/Keypad Front Panel Option.
This potentiometer is used to fine adjust print
darkness to variations in the media. This
potentiometer is not present on the LCD/Keypad
Front Panel Option.