Installation
Electrical Connection - Single and Three Phase
1.
Remove the right and front panels.
2.
Route conduit to the mounting bracket located at the right rear corner of the machine (see
Fig. 9). Be sure to leave a 6 foot/2 meter service loop to the machine.
3.
Remove the right and front panel to access the main terminal blocks.
4.
Follow the Machine Electrical Connection Data Plates for the terminal block connections.
The data plates are Attached close to the blocks (Fig. 11).
Front View
8
WARNING:
Disconnect main power off at the dishwasher and main circuit breaker
before performing work on the circuit.
power source connected to the machine.
Fig. 9 - Cable restraint
Fig. 10 - Power terminal block
There may be more than one
1-Point Machine Connection Data Plate
Mod: DH6000T
Series: M2-STD
For supply connection, use copper connectors in accordance
with local electrical code. Rated Minimum 90°C (194°F).
Overcurrent Protection Device: Time Delay or Inverse Time
Circuit Breaker
Minium Supply Conductor Ampacity
Maximum Supply Overcurrent
Protection Device
Volt: 208-240
Ph: 3
Hz: 60
Fig. 11 - Connection data plate
50/50
AMPS
50/50
AMPS
Amp: 38-34