VHR Cold Water Connection
DH6000-VHR, DH6000T-VHR
COLD
WATER
Minimum/Maximum Incoming
Temperature
55-75º/13-24ºC
Hot Water Connection- DH6000, DH6000T
Standard and VHR
HOT
WATER
Minimum/Maximum Incoming
Temperature
110-140º/43-60ºC
CAUTION: To prevent damage to the dishwasher supply valves, the installing
plumber must thoroughly flush debris from the water supply line before connecting
it to the dishwasher. Damage caused by improper installation is not covered by the
limited warranty.
Water hardness of 3 Grains/US Gal. - 0.83 Imp. Gal - 5.3 mg/L or less.
Install a 3/4" NPT or larger full port shut-off valve in the water supple line
as close to the dishwasher as a possible for servicing.
MINIMUM 3/4" NPT COLD WATER SUPPLY
Minimum Incoming Supply
Flowing Pressure
46-50 PSI
MINIMUM 3/4" NPT HOT WATER SUPPLY
Minimum Incoming Supply
Flowing Pressure
45 PSI/310kPa
Installation
Minimum/Maximum Operating
Flowing Pressure
16 PSI
Minimum/Maximum Operating
Flowing Pressure
16 PSI
5