In-Line And Tank Sensors Normal Operation; In-Line And Tank Sensor Operation Error; Set Detergent Concentrations - Champion M2 Series Installation Manual

Table of Contents

Advertisement

Optional Champion Chemical Dispenser Set-up
Instructions for the Supervisor and Chemical Supplier

IN-LINE and TANK Sensors Normal Operation:

1.
Detergent pump output = 3ml/sec.
2.
Machine fills.
3.
When the lower float is satisfied, detergent
pump runs the fill set point for initial charge.
4.
The detergent pump runs 3 secs. at the
beginning of each wash cycle.

IN-LINE and TANK Sensor Operation Error:

1.
If machine has run one cycle, and tank temperature is 150ºF/65.6ºC or greater, and,
the tank sensor is not satisfied, then the detergent pump will pump the cycle time set
point.
2.
Detergent pump waits 20 secs. and pumps the cycle time set point again or until
the sensor is satisfied.
3.
When the wash pump is running, the
detergent pump will run If the sensor
dectects the detergent is below its
setpoint for 5 consecutive seconds.
4.
This is repeated for two minutes or until
tank sensor is satisfied. The flashing
yellow bottle "LOW DETERGENT ALERT"
will appear if tank sensor is not
satisfied within two minutes.
SET DETERGENT CONCENTRATION --In-line Sensor shown ON (Fig.38):.
1.
The detergent concentration is controlled by the detergent sensor(s) and set-up by
pressing the "CONCENTRATION" button, (Fig. 33) then setting the needed values
according to the charts on page 11 and tritation.
(continued on next page)
Supervisor Menus - Optional Champion Chemical Dispenser Set-up
Fig. 36 - In-line and Tank sensor selected.
Fig. 37 - Tank only or In-line and Tank sensor selected.
Fig. 38 - Detergent Concentration
(continued)