Fault Counters; Temp Offset; Drain Water Tempering (Dwt); Temp Lockout - Champion M2 Series Installation Manual

Table of Contents

Advertisement

Supervisor - Fault Counters, Temp Offset, Temp Lockout, Detergent OFF, Detergent Lockout
SUPERVISOR MENUS

FAULT COUNTERS:

1.
The Fault Counter shows how many times the
machine has a listed fault error.
2.
Only a technician can reset fault counters.

TEMP OFFSET:

1.
Temp Offset allows a service agent to
compensate for variances between
measured and actual temperature.
2.
Only a technician can correct
temperatures, (Fig. 71).

DRAIN WATER TEMPERING (DWT):

(For electric DWT option only)
1.
Drain water tempering is an option that
includes a cold water valve connected to
the drain line to cool the water leaving
the machine.
2.
Refer to Fig. 72 and note the default settings
are OFF. The default time the cold water
valve isenergized is 30 secs. The operating
range is between 1 and 120 secs.
NOTE: The functions listed below are only used by service agents to program
the operation of a machine if equipped with special options, (Fig. 70).
TEMP LOCKOUT: When ON, machine will stop if wash temperature is below
150ºF/65.5ºC. The lockout temperature setting is adjustable.

DOOR LOCK:

When ON, the door lock switch operates as required.
DETERGENT: When ON, the Optional Champion detergent system is operational.
DETERGENT LOCKOUT: When ON, the machine will not operate if detergent is
not detected in the Champion detergent system.
28
(continued)
Fig. 71 - Only a technician can correct temperatures
Fig. 70- MAINT menu
Fig. 72- Drain water tempering settings