Fill Time Exceeded; On For Celsius; Water Refresh; Navigation Buttons - Champion M2 Series Installation Manual

Table of Contents

Advertisement

Supervisor Menus - Fill Time Extended, Water Refresh, On for Celsius, On for French
SUPERVISOR MENUS
FILL TIME EXCEEDED: The time it must take to fill the
wash tank is programmed with the Fill Time Extended
button. If the programmed minutes are exceeded then
the operation screen displays an alarm.
ON FOR CELSIUS: When the button is ON temperatures
are displayed in ºC with the letter "C". By default,
temperatures are displayed in ºF with the letter "F" .
ON FOR FRENCH: When the button is ON descriptions are displayed in French.
By default descriptions are displayed in English.
WATER REFRESH Water Refresh function ensures wash tank water remains clean to
enhance washability by periodically draining one-third of the water in the wash
tank and replacing with fresh water.
1.
Press the Water Refresh button ON.
2.
Press the SetPoint number and enter the number
the number of cycles before wash cycle begins.
3.
Wash Cycle runs.
4.
The next Refresh Cycle runs after the program-
med wash cycles are complete.
Water Refresh Cycle:
1.
MACHINE washes normally. Drain valve opens
at beginning of rinse, and through 15 secs. of
dwelling. Water level is 1/3 low.
2.
Upper float is low. During next cycle, fill comes
on to refill tank.
3.
Booster temperature is low. Machine enters
rinse sentry until booster temperature is satisfied.
4.
Main screen displays the 'WATER REFRESH' alert.
5.
Machine drains, refills and washes normally.

NAVIGATION BUTTONS:

SETTINGS: Press for Supervisor Menu
Back-up to previous screen.
Return to main screen.
22
(continued)
Fig. 49 - Selection buttons
Fig. 50 - Water refresh button
Fig. 51- Adjustable refresh intervals

Hide quick links: