Changing 1 Point To 2-Point Electrical Connections - Champion 64 PRO Series Installation Manual

Two tank rack conveyor dishwasher
Table of Contents

Advertisement

Electrical Connection -
COMPARE ELECTRICAL SUPPLY WITH THE MACHINE ELECTRICAL CONNECTION DATA
PLATE BEFORE CONNECTING POWER TO MACHINE.
THE DATA PLATE IS ADJACENT TO THE INPUT TERMINAL BLOCK.
1-POINT CONNECTION MACHINE HAVE JUMPERS BETWEEN THE INPUT BLOCKS.
REMOVE THE JUMPERS FOR 2-POINT ELECTRICAL CONNECTION.
DISHWASHER
For 1-Point and 2-Point Connection
REMOVE JUMPERS FOR 2-POINT ELECTRICAL CONNECTION
1-point connection jumpers.
Fig. 22 -
Changing 1-Point to 2-Point
Electrical Connection
BOOSTER
For 2-Point Connection Only
1-point connection data plate.
Installation
P/N 115809/B
Fig. 23 -
19