Electrical Connections - Champion E Series Installation/Operation With Service Replacement Parts

Rack conveyor dishwashers
Table of Contents

Advertisement

! ATTENTION !
A qualified electrician must connect the main incoming power to the dishwasher in accordance
with all local codes and regulations or in the absence of local codes in accordance with the
National Electrical Code.
! ATTENTION !
Electrical and grounding connections
must comply with the National Electrical Code
or in the absence of a National Code then
all Local Electrical Codes.
A qualified electrician MUST compare the
electrical power supply with the machine
electrical specifications stamped on the
MACHINE ELECTRICAL CONNECTION
PLATE located inside the control cabinet
before connecting the main power to the
dishwasher.
1. The incoming power to the dishwasher is made in the power terminal block,
located inside the top-mounted control cabinet.
2. The electrician must connect the incoming power based on the information
that is stamped on the Machine Electrical Connection Plate.
3. Any change to the Machine Electrical Connection Plate must be approved
by the factory in advance.
4. A knock-out plug is provided at the rear of the control cabinet for electrical
service connections.
5. Built-in electric booster heaters may have a separate main power connection.
6. Electric blower-dryers have a separate main power connection.
WARNING:
Electrocution or serious injury may result when working on an
energized circuit.
Disconnect power at the main breaker or service disconnect switch
before working on the circuit.
Lock-out and tag the breaker to indicate that work is being
performed on the circuit.

Electrical Connections

MACHINE ELECTRICAL CONNECTION
Installation