Brillion Elite Mini Monitor
Brillion Elite Mini Monitor provides information to the
operator and acts as an interface for clutch control. The
display shows seed shaft rotation, low bin levels, acres
seeded, and clutch engagement. The touch screen allows
the operator to engage the clutch.
See "Brillion Elite Mini Monitor" Chapter for more
information and a detailed guide to the use of your
monitor.
IMPORTANT
The Brillion Elite Mini Monitor System by Loup
utilizes a MUX communication line. Sensors must be
learned into the Monitor. Location of each pre-learned
Smart Shaft Sensor or Bin Level Sensor is important
for proper Monitor display. Each Sensor utilizes 3
wires (+, -, MuxBus) to connect to the system. The
Harnesses do not require a specific Sensor
connection points. Each Sensor is identified in the
Monitor by its own signal.
WARNING
High Power Magnet in use. "High Power Magnet"
on page 1-2
Bin Level Sensors are installed on adjustable
brackets in the outer ends of the Seed Box. When the
sensor is submerged in seed, no alarm will sound. As
the seed level falls below the sensor eye, an alarm will
be indicated on the Brillion Elite Mini Monitor. Raise or
lower the Bin Level Sensor Bracket inside the Seed
Box to the desired seed level.
On the Rear RH side of the Seeder Box is a Smart
Shaft Sensor that is installed on a Sensor Mount that
is attached to the mounting hardware of two seed
cups. The Smart Shaft Sensor is activated by a High
Powered Magnet in a Spacer that is kept in place from
rotating on the Seed Shaft with Set Screws. As the
seed shaft rotates the Smart Shaft Sensor detects the
magnet. When no signal is detected for pre-defined
seconds, an alarm will be indicated on the Brillion
Elite Mini Monitor.
NOTE
If the Smart Shaft Sensor stall alarm occurs, be aware that
the Seeder has not been planting for pre-defined
seconds.
Brillion Elite Mini Monitor provides users the ability to
toggle the seeder clutch on or off.
Brillion Elite Mini Monitor will monitor field and total
acres.
3-12
TABLE OF CONTENTS
Brillion Elite Mini Monitor is operated on a 12-Volt DC
negative ground system. The monitor should be
connected using the existing convenience plug
connection.
The Elite Mini Tractor Harness attaches to the Brillion
Elite Mini Monitor and connects to the Seeder 240"
Extension Harness. See Figure 2-5. The 6-Pin
Connection may be plugged/unplugged at the front of
the Seeder Hitch when hooking/unhooking the
Seeder. This allows the monitor to stay in the tractor
if so desired.
A 4-Pin radar connection is provided as an optional
connection for the speed sensor. The speed signal
may be determined by either the tractor radar or the
speed sensor located on the Seeder.
For service or setup questions contact Loup
Electronics Inc. See "Service And Technical Support"
on page 4-8.
Console w/Clutch Control -
Optional
Basic Operation:
During normal operation the Console LED for the Seed
Shaft will not be illuminated. The Shaft Sensor will be
activated by the Spacer with Magnet installed on the Seed
Shaft being monitored. The Shaft Sensor is a standard
Loup Shaft Sensor, set to 20 second delay timing. When
no signal is detected for 20 seconds by the sensor, the
LED in the Console will illuminate and the audible alarm
will sound indicating a fault. The alarm will become silent
after 30 seconds and will not sound again until the Seed
Shaft returns to a fully functional condition.
NOTE
If the Shaft Sensor stall alarm occurs, be aware that the
Seeder has not been planting for 20 seconds.
The Clutch Master toggle switch allows you to go from
"SEED" to "NO SEED" operations.
F-1021-0422