FIGURE 4-15
7. Place the SBus card in an antistatic bag for protection.
8. If the SBus card is not immediately replaced, install a filler panel (part number
340-2305) on the I/O+ board back panel opening. To secure the filler panel, use the
screws that were removed in Step 3.
Caution – Be sure to install the filler panel right-side up. Installing it upside down
creates a gap at the top edge of the SBus slot opening that can impair system cooling
and FCC regulatory compliance.
9. Replace the I/O+ board. Use the procedures in Section 4.5.3 "Installing a Board"
on page 4-11."
4.5.4.3
Installing an SBus Card
Removing Adapter and Card Retainer
Note – If the new SBus card does not have an adapter plate or card retainer, proceed
to Section t "Installation" on page 4-22.
4-18
Sun Enterprise 6500/5500/4500 Systems Reference Manual • April 1998
Removing or Installing an SBus Card