Defective I/O+ Interface Board - Sun Microsystems Enterprise 6500 Reference Manual

Hide thumbs Also See for Enterprise 6500:
Table of Contents

Advertisement

10.4

Defective I/O+ Interface Board

Interface boards are hot-pluggable in many instances.
Begin
INDICATION
System error message or
LED code identifies
a specific board
Board not identified or
intermittent problem
End
FIGURE 10-4
TEST/PROCEDURE
Locate indicated board.
Check LEDs on board to verify ASR
has deactivated the board.
Replace the board or device.
Board is not active until system is
booted.
Check system message files.
Start prtdiag log file, if necessary, to
record error messages.
Run SunVTS to test suspected
boards, CPUs, SIMMs, power
supplies, other devices.
Check I/O cable connections.
Ensure JTAG Test Jumper on PCI
cards is disabled/removed.
Check related PCM.
Replacing I/O Interface
REFERENCE
LED code must be Off-On-
See Section 3.3 "Hot-Plug
See Section 9.3.3.2
Refer to SunVTS User's
See Section 4.5.7.2
See
Chapter 10
Flow Diagrams for Troubleshooting
Off. See
.
TABLE 9-2
Feature."
"Running prtdiag."
Guide.
"Replacing or Installing
a PCI Card."
.
FIGURE 10-7
10-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enterprise 5500Enterprise 4500

Table of Contents