Defective CPU/Memory+ Board

CPU/Memory+ boards are hot-pluggable.
Begin
INDICATION
System error message or
LED code identifies a
specific board
Board not identified or
intermittent problem
End
FIGURE 10-3
10-4
Sun Enterprise 6500/5500/4500 Systems Reference Manual • April 1998
TEST/PROCEDURE
Locate indicated board.
Check LEDs on board to verify
ASR has deactivated the
board.
Replace the board or device.
Board is not active until system is
booted.
Check /var/adm/messages
Run SunVTS to test suspected
boards, CPUs, SIMMs,
power supplies, other
devices.
Check related modular power
supply.
Diagnosing CPU/Memory+ Board Problems
REFERENCE
LED code must be Off-On-Off.
See
.
TABLE 9-2
See Section 3.3 "Hot-Plug
Feature."
Refer to SunVTS User's Guide.
See
.
FIGURE 10-7