Figure 3-13 Ejecting A Simm - Sun Microsystems Enterprise 6500 Reference Manual

Hide thumbs Also See for Enterprise 6500:
Table of Contents

Advertisement

3. Use the system error messages to locate the slot (
need to replace.
4. Eject the faulty SIMM by pressing down on the ejection levers on both sides of
the SIMM connector (
FIGURE 3-13
5. Holding the SIMM by its edges, remove it from the slot and place it on an
antistatic surface.
3.4.5.2
Installing a Memory Module
Requirements
All banks must have the same size SIMMs, however, SIMMs from different
manufacturers are interchangeable in a single bank if the SIMMs all have the same
capacity and speed. Sort the SIMMs into banks of eight using the same size SIMMs.
3-18
Sun Enterprise 6500/5500/4500 Systems Reference Manual • April 1998
FIGURE 3-13
Ejecting a SIMM
FIGURE 3-12
).
) for the SIMM you