2.2 Interface Menu

2.2.1 Control Mode

2.2.1.1 LCD Interface
The Interface Menu allows you to put the tape library into various modes from
which you can control the tape library.
The Interface Menu consists of the following submenus:
Control mode
Configuration 25-Pin Port (not supported)
Configuration 9-Pin Port (not supported)
Configuration 4-Pin Port (not supported)
The Control Mode Menu determines what controls the motions of the CHM.
The SPARCstorage Library must be in one of the three sequential modes in
order to use the SunDiag
control modes:
LCD Interface
SCSI Interface
Sequential 1
Sequential 2
Dual Sequential
25-Pin Serial Port (not supported)
9-Pin Serial Port (not supported)
4-Pin Serial Port (not supported)
Use
to scroll up through the control mode functions and
LCD Interface Mode is required when you want to control the motions of the
CHM though the display panel. For example, diagnostics can be performed
that test individual motions, such as picking and placing cartridges from
specific locations.
Note – You must be in LCD interface mode to run certain tests in the
Maintenance Menu.
SPARCstorage Library Menu Functions
system exerciser. The tape library has the following