CONFIGURING FALLBACK SETTING

Use to set the output valid-video detection fallback input for the MINI-T-NET and the
NET-164 (see Table 4, Setting Fallback Settings from Front Panel). If an output loses
video, it will be switched to a user-defined input that can be relied upon to have video.
The user defines the number of seconds of invalid video before the switch is made.
NOTE:
The fallback configuration may also be set from WinNET (see "Configuring
Controller Properties," on page 67).
FALLBACK CONFIGURATION STEPS
1. From the "MAIN MENU" screen, press "↑" or
"↓" to proceed to "Setup."
2. Press "→" to select "Setup."
3. Press "↑" or "↓" to proceed to "Fallback
Configuration."
4. Press "→" to select "Fallback Configuration."
5. Press "↑↓" to change fallback configuration.
6. Press "→" to enter next screen.
7. Either press "→" again to save your changes
or "←" to abort changes.
LEIGHTRONIX, INC.
2010-07-09
Table 4, Setting Fallback Settings from Front Panel
Firmware Ver. 1.00.42/Software Ver. 1.0.2.6
Controller Installation & Configuration
CORRESPONDING SCREEN DISPLAYS
MAIN MENU
Setup
SETUP MENU
Fallback Configuration
Output 1 fallback to
Input 8 after -- seconds
NOTES:
The MINI-T-NET doesn't have the output field
as it is a single channel switcher.
The "- -" in the seconds field means that when a
loss of valid-video is detected no switch will
occur. A range of 1–99 seconds may be
entered in the seconds field to define the delay
time before the fallback switch will occur.
Press ~ to save loss
of video fallback.
NET Series