Image Adjustments; Boresight Alignment - Christie J Series Service Manual

Hide thumbs Also See for J Series:
Table of Contents

Advertisement

Section 4: Parts and Module Replacement

4.12 Image Adjustments

Use the following guidelines for safely servicing Christie equipment that needs to remain energized (live)
during a service procedure.
Only Christie accredited technicians who are knowledgeable about the hazards associated with hazardous
voltage, ultraviolet exposure, and high temperatures are authorized to assemble, install, and service Christie
equipment.
To make sure you remain safe when servicing energized (live) Christie equipment:
• Locate the main AC power shut off prior to servicing the equipment. This will allow you to turn the power
off quickly in an emergency.
• Disconnect the projector from the communication and management network so it cannot receive commands
to turn the lamp on, open the douser, and move the lens.
• Familiarize yourself with all potential safety hazards prior to servicing the equipment. This includes, but is
not limited to, the location and accessibility of hazardous voltages.
• Read and understand all written procedures prior to commencing a service procedure.
• Understand and follow all local safety codes and requirements when servicing energized (live) equipment.
• Perform equipment service in a location free of obstructions and other hazards. For example, you must have
an unobstructed view of the area being serviced.
• Wear personal protective equipment (PPE) clothing appropriate to the service you are performing. This
includes, but is not limited to, protective (electrically insulated) footwear, safety glasses, and gloves rated for
the working voltage of the equipment you are servicing.

4.12.1 Boresight Alignment

1. Display the boresight test pattern by pressing the T
and press the soft key that displays test on the LCD display, then U
E
NTER
.
2. Focus the image on cross-hair pattern I. Evaluate the focus on cross-hair image II and III. If all 3 images
are in focus, no further action is required. If boresight is required, continue to step 3.
3. If boresight is required, refer to Figure 4-1 Cross Hair Pattern to understand how the adjustment screws
on the lens mount affect the corresponding cross-hairs on the test pattern.
NOTE: The cap screw in Figure 4-2(A) may be under a plastic cap, remove and retain before adjusting.
4. Use a 5 mm hex driver to loosen (3) locking setscrews on the lens mount, see Figure 4-2(B), below.
4-32
EST
key on the remote keypad or use the built-in keypad
A
P
RROW
J Series 1000W and 1200W Service Manual
K
EY
to cycle to boresight, then
020-100725-04 Rev. 1 (07-2015)