To save contents of the accumulative register into the operation result. (the result operation pointer
pluses 1)
Mnemonic
MRD
Operand
Explanations:
Reading content of the operation result to the accumulative register. (the pointer of operation result
doesn't move)
Mnemonic
MPP
Operand
Explanations:
Reading content of the operation result to the accumulative register. (the stack pointer will decrease
1)
Program Example:
Ladder diagram:
MPS
X0
MRD
MPP
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

Reads the current result of the internal PLC operations

Reads the current result of the internal PLC operations
X1
Y1
X2
M0
Y2
END
Appendix D How to Use PLC Function|
Function
None
Function
None
Command code: Operation:
LD
X0
Load contact A of X0
MPS
Save in stack
AND
X1
Connect to contact A of X1 in
series
OUT
Y1
Drive Y1 coil
MRD
Read from the stack (without
moving pointer)
AND
X2
Connect to contact A of X2 in
series
OUT
M0
Drive M0 coil
MPP
Read from the stack
OUT
Y2
Drive Y2 coil
END