Program Example:
Ladder diagram:
X0
X1
Mnemonic
SET
Operand
Explanations:
When the SET command is driven, its specific device is set to be "ON," which will keep "ON" whether
the SET command is still driven. You can use the RST command to set the device to "OFF".
Program Example:
Ladder diagram:
X0
Y0
Mnemonic
RST
Operand
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
Y1
X0~X17
Y0~Y17
--
Command code:
LD
SET
Y1
ANI
SET
X0~X17
Y0~Y17
--
Appendix D How to Use PLC Function|
Command code: Operation:
LDI
X0
Load contact B of X0
AND
X1
Connect to contact A of X1 in
series
OUT
Y1
Drive Y1 coil
Function
Latch (ON)
M0~M159
Operation:
X0
Load contact A of X0
Y0
Connect to contact B of Y0 in series
Y1
Y1 latch (ON)
Function
Clear the contacts or the registers
M0~M159
T0~15
C0~C7
--
--
T0~15
C0~C7
D0~D29
--
D0~D29
--
D-37