Preparation For Installation And Wiring; Ambient Conditions; Minimum Mounting Clearances - Delta Electronics AC Motor Drive VFD-E User Manual

Vfd-e high performance/flexible options/micro type ac motor drives
Table of Contents

Advertisement

Chapter 1 Introduction|

1.2 Preparation for Installation and Wiring

1.2.1 Ambient Conditions

Install the AC motor drive in an environment with the following conditions:
Operation
Storage
Transportation
Pollution
Degree

Minimum Mounting Clearances

Frame A Mounting Clearances
Option 1 (-10 to +50°C)
120mm
120mm
1-8
Air Temperature:
Relative Humidity:
Atmosphere
pressure:
Installation Site
Altitude:
Vibration:
Temperature:
Relative Humidity:
Atmosphere
pressure:
Vibration:
2: good for a factory type environment.
Option 2 (-10 to +40°C)
-10 ~ +50°C (14 ~ 122°F) for UL & cUL
-10 ~ +40°C (14 ~ 104°F) for side-by-side mounting
<90%, no condensation allowed
86 ~ 106 kPa
<1000m
2
<20Hz: 9.80 m/s
(1G) max
20 ~ 50Hz: 5.88 m/s
-20°C ~ +60°C (-4°F ~ 140°F)
<90%, no condensation allowed
86 ~ 106 kPa
2
<20Hz: 9.80 m/s
(1G) max
20 ~ 50Hz: 5.88 m/s
120mm
120mm
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
2
(0.6G) max
2
(0.6G) max
Air flow
Air Flow

Hide quick links:

Advertisement

Table of Contents
loading