D.4.2 Devices Functions

The Function of Input/output Contacts

The function of input contact X: input contact X reads input signal and enter PLC by
connecting with input equipment. It is unlimited usage times for A contact or B contact of
each input contact X in program. The On/Off of input contact X can be changed with the
On/Off of input equipment but can't be changed by using peripheral equipment (WPLSoft).

The Function of Output Contact Y

The mission of output contact Y is to drive the load that connects to output contact Y by
sending On/Off signal. There are two kinds of output contact: one is relay and the other is
transistor. It is unlimited usage times for A or B contact of each output contact Y in program.
But there is number for output coil Y and it is recommended to use one time in program.
Otherwise, the output result will be decided by the circuit of last output Y with PLC program
scan method.
D-20
For latched
For general
For special
Specifications
T0~T15, 16 points
C0~C7, 8-bit counter, 8 points
D0~D9, 10 points
D10~D29, 20 points
D1000~D1044, 45
points
K-32,768 ~ K32,767 (16-bit operation)
H0000 ~ HFFFF (16-bit operation)
RS485 (slave)
Built-in 2 analog inputs and 1 analog output
Digital input/output card (A/D, D/A card)
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
Remarks
When timer attains, the
contact of timer will be
On.
When timer attains, the
contact of timer will be
On.
Total is
It can be memory area
75
for storing data.