Group 6 Protection Parameters - Delta Electronics AC Motor Drive VFD-VE Series User Manual

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Group 5 Motor Parameters
Pr.
Explanation
05-00
Motor Auto Tuning
05-01
Full-load Current of
Motor 1
Rated power of Motor 1
05-02
Rated speed of Motor 1
05-03
(rpm)

Group 6 Protection Parameters

New setting 0 for Pr.06-01, new settings 64~65 for Pr.06-17~Pr.06-22 and new parameters 06-
32~06-36.
Pr.
Explanation
Over-voltage Stall
06-01
Prevention
06-17
Present Fault Record
Second Most Recent
06-18
Fault Record
Third Most Recent Fault
06-19
Record
06-20
Fourth Most Recent
Fault Record
06-21
Fifth Most Recent Fault
Record
06-22
Sixth Most Recent Fault
Record
Revision August 2008, 03VE, SW V2.04
Settings
0: No function
1: Rolling test
2: Static Test
3: Reserved
40-100%
0~655.35
0~65535
1710 (60Hz, 4 poles), 1410 (50Hz, 4 poles)
Settings
0.0: Disable
350.0~450.0Vdc
700.0~900.0Vdc
0: No fault
1: Over-current during acceleration (ocA)
2: Over-current during deceleration (ocd)
3: Over-current during constant speed (ocn)
4: Ground fault (GFF)
5: IGBT short-circuit (occ)
6: Over-curent at stop (ocS)
7: Over-voltage during acceleration (ovA)
8: Over-voltage during deceleration (ovd)
9: Over-voltage during constant speed (ovn)
10: Over-voltage at stop (ovS)
11: Low-voltage during acceleration (LvA)
12: Low-voltage during deceleration (Lvd)
13: Low-voltage during constant speed (Lvn)
14: Low-voltage at stop (LvS)
15: Phase loss (PHL)
16: IGBT heat sink over-heat (oH1)
17: Heat sink over-heat (oH2)(for 40HP above)
18: TH1 open loop error (tH1o)
19: TH2 open loop error (tH2o)
20: Fan error signal output
21: over-load (oL) (150% 1Min)
22: Motor 1 over-load (EoL1)
23: Motor 2 over-load (EoL2)
24: Motor PTC overheat (oH3)
25: Fuse error (FuSE)
26: over-torque 1 (ot1)
27: over-torque 1 (ot2)
28: Reserved
29: Reserved
30: Memory write-in error (cF1)
31: Memory read-out error (cF2)
32: Isum current detection error (cd0)
33: U-phase current detection error (cd1)
34: V-phase current detection error (cd2)
35: W-phase current detection error (cd3)
36: Clamp current detection error (Hd0)
37: Over-current detection error (Hd1)
38: Over-voltage detection error (Hd2)
Chapter 4 Parameters|
Factory
VF
VFPG SVC
Setting
0
#.##
#.##
1710
Factory
VF VFPG SVC FOCPG TQRPG
Setting
380.0
760.0
0
0
0
0
0
0
FOCPG TQRPG
4-33

Hide quick links:

Advertisement

Table of Contents
loading