Group 9 Communication Parameters
Pr.
Explanation
Multi-function Output
09-21
Status
AFM2 Status
09-22
AFM3 Status
09-23
Group 10 Speed Feedback Control Parameters
New parameters 10-29~10-30
Pr.
Explanation
ASR (Auto Speed
10-04
Regulation) Control ( P) 1
ASR (Auto Speed
10-06
Regulation) Control ( P) 2
P Gain of Zero Speed
10-21
PG Mechanical Gear A2 1~5000
10-29
PG Mechanical Gear B2 1~5000
10-30
Group 11 Advanced Parameters
Updated parameters 11-00 and 11-09~11-10 and new parameters 11-18~11-40.
Pr.
Explanation
System Control
11-00
Detection Time for
11-07
Phase-loss
Reserved
11-08
Level of Phase-loss
11-09
Speed Feed Forward
Gain
11-10
Zero-speed
11-11
Bandwidth
Speed Response of
11-12
Flux Weakening Area
Notch Filter Depth
11-13
Notch Filter
11-14
Frequency
Gain Value of Slip
11-15
Compensation
Low-pass Filter Time
11-16
of Keypad Display
Low-pass Filter Time
11-17
of PG2 Pulse Input
APR Gain
11-18
APR Curve Time
11-19
11-20
|
Reserved
11-28
Accumulative
Operation Time of
11-29
Phase-loss
11-30
|
Reserved
11-40
Revision August 2008, 03VE, SW V2.04
Settings
0~65535
0~4095
0~4095
Settings
0~40
0~40
0~40
Settings
bit 0: ASR Auto tuning
bit 1: Inertia estimate
bit 2: Zero Servo
bit 3: Reserved
bit 4: Enable gain adjustment of position loop KP
0.01~600.00 sec
0.0~320.0
0~100%
0~40Hz
0: Disable
0~150%
0~20db
0.00~200.00
0.00~1.00
0.001~65.535sec
0.000~65.535sec
0.00~40.00
0.00~655.35 sec
0~65535 (hour)
Chapter 4 Parameters|
Factory
VF VFPG SVC FOCPG TQRPG
Setting
Read-
only
Read-
only
Read-
only
Factory
VF VFPG SVC FOCPG TQRPG
Setting
10
10
10
100
100
Factory
VF
VFPG SVC FOCPG TQRPG
Setting
0
0.20
60.0
0
10
65
0
0.00
1.00
0.100
0.100
10.00
3.00
0
4-37