Delta Electronics AC Motor Drive VFD-VE Series User Manual page 112

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Settings
Functions
optimal accel./decel. time 01/02/03/04 first. When this function is enabled, OFF is for
Switch between drive
14
settings 1 and 2
Operation speed
15
command form AVI
Operation speed
16
command form ACI
Operation speed
17
command form AUI
18
Emergency Stop (07-36)
19
Digital Up command
20
Digital Down command
21
PID function disabled
22
Clear counter
Input the counter value
23
(multi-function input
command 6)
24
FWD JOG command
25
REV JOG command
TQC+PG/FOC+PG
26
model selection
27
ASR1/ASR2 selection
28
Emergency stop (EF1)
Signal confirmation for Y-
29
connection
Signal confirmation for
30
Δ−connection
High torque bias (by
31
Pr.07-29)
Revision August 2008, 03VE, SW V2.04
auto mode and ON is for linear accel./decel.
When this function is enabled, the drive will start to use motor
2 parameters.
When this function is enabled, the source of the frequency will
force to be AVI.
When this function is enabled, the source of the frequency will
force to be ACI.
When this function is enabled, the source of the frequency will
force to be AUI.
When this function is enabled, the drive will ramp to stop by
Pr.07-36 setting.
When this function is enabled, the frequency will be increased
and decreased. If this function keeps ON, the frequency will
be increased/decreased by Pr.02-07/Pr.02-08. This function is
the same as the ▲▼ key on the keypad.
When this function is ON, the PID function is disabled.
When this function is enabled, it will clear current counter
value and display "0". Only when this function is disabled, it
will keep counting upward.
When this function is enabled, the counter value will increase
1.
When this function is enabled, the drive will execute forward
Jog command.
When this function is enabled, the drive will execute reverse
Jog command.
OFF: FOC+PG speed control mode.
ON: TQR+PG torque control mode.
ON: speed will be adjusted by ASR 2 setting.
OFF: speed will be adjusted by ASR 1 setting.
When it is ON, the drive will execute emergency stop. (it will
have fault code record)
When it is ON, the drive will operate by 1st V/f.
When it is ON, the drive will operate by 2nd V/f.
The high torque bias is according to the Pr.07-29 setting.
Chapter 4 Parameters|
Descriptions
4-63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents