Delta Electronics AC Motor Drive VFD-VE Series User Manual page 84

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Pr.
Explanation
Wind Mode
08-22
Mechanical Gear Ratio
08-23
A
Mechanical Gear Ratio
08-24
B
Source of the Tension
08-25
Command/Line Speed
PID Target Value of
08-26
Tension/Line Speed
Source of Tension/Line
08-27
Speed PID Feedback
Auto-tuning Tension
08-28
PID
Tension PID P1
08-29
Tension PID I1
08-30
Reserved
08-31
Tension PID P2
08-32
Tension PID I2
08-33
Reserved
08-34
PID/Line Speed Output
08-35
Status
Tension/Line Speed PID
08-36
Output Limit
Source of Line Speed
08-37
Input Command
Max. Line Speed
08-38
Min. Line Speed
08-39
Pulse Number for Each
08-40
Meter
Current Line Speed
08-41
Source of Reel
08-42
Diameter
Max. Reel Diameter
08-43
Empty Reel Diameter
08-44
Source of Initial Reel
08-45
Diameter
Initial Reel Diameter
08-46
Initial Reel Diameter 1
08-47
Initial Reel Diameter 2
08-48
Number of Pulse per
08-49
Revolution
Coil Number for Each
08-50
Layer
Material Thickness
08-51
Filter Time of Reel
08-52
Diameter
Auto Compensation of
08-53
Revision August 2008, 03VE, SW V2.04
Settings
0: Rewind
1: Unwind
1-65535
1-65535
0: Parameter setting (Pr.08-26)
1: RS-485 communication setting (Pr.08-26)
2: Analog input (Pr. 03-00~03-02 is set to 14 PID
target value of tension, 03-00~03-02 is set to 12
line speed)
0.0~100.0%
0: Analog input (Pr. 03-00~03-02 is set to 11 PID
feedback of tension)
1: Pulse input (Pr.08-40)
0: Disable
1: Reel diameter (08-29~08-31corresponds to 08-
44, 08-32~08-34 corresponds to 08-43)
2: Frequency (08-29~08-31 corresponds to 01-07,
08-32~08-34 corresponds to 01-00)
0.0~1000.0
0.00~500.00 sec
0.0~1000.0
0.00~500.00 sec
0: Positive output
1: Negative output
0~100.00% (according to Pr,01-00)
0: Disable
1: Analog input (Pr. 03-00~03-02 is set to 12 line
speed)
2: RS-485 communication setting (Pr.08-41)
3: Pulse input (Pr.08-40)
4: DFM-DCM pulse input (Pr.02-18)
0.0~3000.0m/min
0.0~3000.0m/min
0.0~6000.0
0.0~3000.0m/min
0: Calculated by line speed
1: Calculated by integrating thickness (encoder
is on reel shaft)(Pr.08-49~51, Pr.10-15)
2: Calculated by integrating thickness (encoder
is on motor)(Pr.08-23~08-24, 08-50~08-51, 10-
00~10-01)
3: Calculated by analog input (Pr.03-00~03-02 is
set to 13)
1.0~6000.0mm
1.0~6000.0mm
0: RS-485 communication setting (Pr.08-46)
1: Analog input (Pr.03-00-Pr.03-02 is set to 13)
1.0~6000.0mm
1.0~6000.0mm
1.0~6000.0mm
1~10000ppr
0.001~60.000mm
0.001~60.000mm
0.00 to 100.00 seconds
0: Disable
Chapter 4 Parameters|
Factory
VF VFPG SVC FOCPG TQRPG
Setting
0
100
100
0
50.0
0
50.0
1.00
50.0
1.00
0
20.00
0
1000.0
0.0
0.0
0.0
0
6000.0
1.0
0
1.0
1.0
1.0
1
1.000
1.000
1.00
1.00
4-35