Delta Electronics AC Motor Drive VFD-VE Series User Manual page 89

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Chapter 4 Parameters|
00-04
Content of Multi-Function function Display
Settings 0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
4-40
Display the output current in A supplied to the motor
Display the counter value which counts the number of
pulses on TRG terminal
Display actual output frequency (H)
Display the actual DC BUS voltage in VDC of the AC
motor drive
Display the output voltage in VAC of terminals U, V, W
to the motor.
Display the power factor angle in º of terminals U, V, W
to the motor.
Display the output power in kW of terminals U, V and W
to the motor.
Display the actual motor speed in rpm (enabled when
using with PG card).
Display the estimated value of torque in Nm as it relates
to current.
Display PG position. When Pr.10-01 is set to 1 or 2, it
means that motor angle is 0~4XPr.10-00.
Display analog feedback signal value in %.
Display the signal of AVI analog input terminal in %.
Range 0~10V corresponds to 0~100%. (1.)
Display the signal of ACI analog input terminal in %.
Range 4~20mA/0~10V corresponds to 0~100%. (2.)
Display the signal of AUI analog input terminal in %.
Range -10V~10V corresponds to 0~100%. (3.)
Display the temperature of heat sink in °C.
Display the temperature of IGBT in °C.
Display digital input status ON/OFF (i)
Display digital output status ON/OFF (o)
Display multi-step speed
The corresponding CPU pin status of digital input (i.)
The corresponding CPU pin status of digital output (o.)
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
Revision August 2008, 03VE, SW V2.04