Delta Electronics AC Motor Drive VFD-VE Series User Manual page 119

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Chapter 4 Parameters|
12: Mechanical brake release (Pr.02-31)
13: Overheat
14: Software brake signal
15: PID feedback error
16: Slip error (oSL)
17: Terminal count value attained (Pr.02-16)
18: Preliminary count value attained (Pr.02-17)
19: Baseblock (B.B.) Indication
20: Warning output
21: Over voltage warning
22: Over-current stall prevention warning
23: Over-voltage stall prevention warning
24: Operation mode indication
25: Forward command
26: Reverse command
27: Output when current >= Pr.02-32
28: Output when current < Pr.02-32
29: Output when frequency >= Pr.02-33
30: Output when frequency < Pr.02-33
31: Y-connection for the motor coil
32:
connection for the motor coil
Δ
33: Zero speed (actual output frequency)
34: Zero speed with Stop (actual output frequency)
35: Error output selection 1 (Pr.06-23)
36: Error output selection 2 (Pr.06-24)
37: Error output selection 3 (Pr.06-25)
38: Error output selection 4 (Pr.06-26)
39: Position attained (Pr.10-19)
40: Speed attained (including zero speed)
41: Multi-position attained
42: Crane function
43: Motor zero-speed output (Pr.02-43)
44: Max. reel diameter attained
45: Empty reel diameter attained
46: Broken belt detection
47: Break release at stop
48: Error PID feedback of tension
49: Reserved
50: Reserved
Settings
Functions
0
No Function
1
Operation Indication
Master Frequency
2
Attained
Desired Frequency
3
Attained 1 (Pr.02-19)
4-70
Settings
Active when the drive is not at STOP.
Active when the AC motor drive reaches the output frequency
setting.
Active when the desired frequency (Pr.02-19) is attained.
Control Mode
VF
VFPG
SVC
Descriptions
Revision August 2008, 03VE, SW V2.04
FOCPG TQRPG

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents