When it is set to 1, 3 or 4, the current line speed will be saved into Pr.08-41 via analog and
pulse command. When it is set to 2, it can change the setting of Pr.08-41 (current line speed)
via communication.
When it is set to 3 or 4, pulse signal needs to be connected to PG2 of the PG card and then
set the PG type by Pr.10-15.
When it is set to 3, it needs to use with Pr.08-40.
When it is set to 4, Pr.02-18 setting needs to be set to the DFM output value of previous driver
as shown in the following before setting Pr.08-38.
motor
D riv er 1
T P
(02-18)
DFM
08-38

Max. Line Speed

Control
VF
VFPG
mode
Settings
08-39

Min. Line Speed

Revision August 2008, 03VE, SW V2.04
3
Pulse input (Pr.08-40)
4
DFM-DCM pulse input (Pr.02-18)
tractor
DF M
DCM
SVC
FOCPG TQRPG
0.0 to 3000.0 m/min
Wind
the setting of P r,02-18 of motor 2
= the setti ng of Pr.02-18 of m otor 1
motor
Pr.10- 15 of motor 2
should be set to 3 or 4
Driv er 2
PG 2
A2
T P
/A2
B2
/B2
AB2
DCM
Chapter 4 Parameters|
Factory Setting: 1000.0
Unit: 0.1
Unit: 0.1
4-129