Chapter 4 Parameters|
When integral time is set to 0, it is disabled. Pr.10-08 defines the switch frequency for the
ASR1 (Pr.10-04, Pr.10-05) and ASR2 (Pr.10-06, Pr.10-07).
When using multi-function input terminals to switch ASR1/ASR2, the diagram will be shown as
follows.
Setting multi-function input terminal to 27
10-09

ASR Primary Low Pass Filter Gain

Control
FOCPG
mode
Settings
It defines the filter time of the ASR command.
10-10

PG Stall Level

Control
VFPG FOCPG
mode
Settings
This parameter determines the maximum PG feedback signal allowed before a fault occurs.
(max. output frequency Pr.01-00 =100%)
10-11

PG Stall Detection Time

Control
VFPG FOCPG
mode
Settings
10-12

PG Slip Range

Control
VFPG FOCPG
mode
4-152
PI
10-06
10-07
10-04
10-05
10-21
10-22
5Hz
0Hz
(ASR1/ASR2 switch)
ASR 1
0.000 to 0.350 sec
0 to 120% (0: disable)
0.0 to 2.0 sec
5Hz
10-08
ON
OFF
ASR 2
0.1 sec
Hz
OFF
ASR 1
0.1 sec
Factory Setting: 0.008
Factory Setting: 115
Factory Setting: 0.1
Factory Setting: 50
Revision August 2008, 03VE, SW V2.04
Unit: 0.001
Unit: 1
Unit: 0.1
Unit: 1