Group 7 Special Parameters - Delta Electronics AC Motor Drive VFD-VE Series User Manual

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Chapter 4 Parameters|

Group 7 Special Parameters

Pr.
Explanation
Software Brake Level
07-00
DC Brake Current
07-01
Level
DC Brake Time during
07-02
Start-up
DC Brake Time during
07-03
Stopping
Start-point for DC
07-04
Brake
07-05
DC Brake Voltage
Gain
Momentary Power
07-06
Loss Operation
Selection
Maximum Allowable
07-07
Power Loss Time
B.B. Time for Speed
07-08
Search
Current Limit for
07-09
Speed Search
Base-block Speed
07-10
Search
Auto Restart after
07-11
Fault
Speed Search during
07-12
Start-up
Decel. Time Selection
07-13
for Momentary Power
Loss
DEB Return Time
07-14
Dwell Time at Accel.
07-15
Dwell Frequency at
07-16
Accel.
Dwell Time at Decel.
07-17
Dwell Frequency at
07-18
Decel.
Fan Control
07-19
Torque Command
07-20
Torque Command
07-21
Source
Maximum Torque
07-22
Command
Filter Time of Torque
07-23
Command
07-24
Speed Limit Selection
Torque Mode +Speed
07-25
Limit
Torque Mode-Speed
07-26
Limit
4-16
Settings
230V: 350.0~450.0Vdc
460V: 700.0~900.0Vdc
0~100%
0.0~60.0 sec
0.0~60.0 sec
0.00~600.00Hz
1~500
0: Operation stop after momentary power loss
1: Operation continues after momentary power loss,
speed search starts with the Master Frequency
reference value
2: Operation continues after momentary power loss,
speed search starts with the minimum frequency
0.1~5.0 sec
0.1~5.0 sec
20~200%
0: Stop operation
1: Speed search starts with last frequency command
2: Speed search starts with minimum output frequency
0~10
0: Disable
1: Speed search from maximum frequency
2: Speed search from start-up frequency
3: Speed search from minimum frequency
0: Disable
st
1: 1
decel. time
nd
2: 2
decel. time
rd
3: 3
decel. time
th
4: 4
decel. time
5: Current decel. time
6: Auto decel. Time
0.0~25.0 sec
0.00~600.00sec
0.00~600.00Hz
0.00~600.00sec
0.00~600.00Hz
0: Fan always ON
1: 1 minute after AC motor drive stops, fan will be OFF
2: AC motor drive runs and fan ON, AC motor drive
stops and fan OFF
3: Fan ON to run when preliminary heat sink
temperature attained
4: Fan always OFF
-100.0~100.0% (Pr. 07-22 setting=100%)
0: Digital keypad
1: RS485 serial communication (RJ-11)
2: Analog signal (Pr.03-00)
0~500%
0.000~1.000 sec
0: By Pr.07-25 and Pr.07-26
1: Frequency command source (Pr.00-20)
0~120%
0~120%
Factory
VF
VFPG SVC
Setting
380.0
760.0
0
0.0
0.0
0.00
50
0
2.0
0.5
150
0
0
0
0
0.0
0.00
0.00
0.00
0.00
0
0.0
0
100
0.000
0
10
10
Revision August 2008, 03VE, SW V2.04
FOCPG TQRPG

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents