Group 3 Analog Input/Output Parameters
03-00

Analog Input 1 (AVI)

03-01

Analog Input 2 (ACI)

03-02

Analog Input 3 (AUI)

0: No function
1: Frequency command (torque limit under TQR control
mode)
2: torque command (torque limit under speed mode)
3: Torque compensation command
4: PID target value (refer to group 8)
5: PID feedback signal (refer to group 8)
6: P.T.C. thermistor input value
7: Positive torque limit
8: Negative torque limit
9: Regenerative torque limit
10: Positive/negative torque limit
11: PID feedback signal of tension
12: Line speed
13: Reel diameter
14: PID target value of tension (tension closed-loop)
15: Tension setting (tension open-loop)
16: Zero-speed tension
17: Tension taper
When it is frequency command or TQR speed limit, the corresponding value for 0~±
10V/4~20mA is 0 – max. output frequency(Pr.01-00)
When it is torque command or torque limit, the corresponding value for 0~±10V/4~20mA is 0 –
max. output torque (Pr.07-22).
When it is torque compensation, the corresponding value for 0~±10V/4~20mA is 0 – rated
torque.
Revision August 2008, 03VE, SW V2.04
Settings
Chapter 4 Parameters|
Control Mode
VF
VFPG
SVC
Factory Setting: 1
Factory Setting: 0
Factory Setting: 0
FOCPG TQRPG
4-79