Current Limit; Electronic Thermal Relay Selection (Motor 1); Electronic Thermal Relay Selection (Motor 2); Electronic Thermal Characteristic For Motor 1 - Delta Electronics AC Motor Drive VFD-VE Series User Manual

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

06-12

Current Limit

Control
FOCPG TQRPG
mode
Settings
It is used to set the current limit.
06-13

Electronic Thermal Relay Selection (Motor 1)

Control
VF
VFPG
mode
Settings
06-27

Electronic Thermal Relay Selection (Motor 2)

Control
VF
VFPG
mode
Settings
It is used to prevent self-cooled motor overheats under low speed. User can use electrical
thermal relay to limit driver's output power.
06-14

Electronic Thermal Characteristic for Motor 1

Control
VF
VFPG
mode
Settings
06-28
Electronic Thermal Characteristic for Motor 2
Control
VF
VFPG
mode
Settings
Revision August 2008, 03VE, SW V2.04
current
Pr.06-08, 06-11
0 to 250%
SVC
FOCPG TQRPG
0
Operate with a Inverter Motor (forced external cooling)
1
Operate with a Standard Motor (self-cooled by fan)
2
Disabled
SVC
FOCPG TQRPG
0
Operate with a Inverter Motor (forced external cooling)
1
Operate with a Standard Motor (self-cooled by fan)
2
Disabled
SVC
FOCPG TQRPG
30.0 to 600.0 sec
SVC
FOCPG TQRPG
30.0 to 600.0 sec
Chapter 4 Parameters|
5%
Pr.06-07,
Pr.06-10
Factory Setting: 150
Factory Setting: 2
Factory Setting: 2
Factory Setting: 60.0
Factory Setting: 60.0
Unit: 1
Unit: 0.1
Unit: 0.1
4-99