8.5.3 Restart signal
Part
Detection signal 1
The Detection signal 1 and Detection signal 2 outputs go to ON-state as soon as the last
channel has correctly completed the transition 0 -> 1 -> 0.
Detection signal 2
Restart signal CH1
Interchangeable channel. Both channels of Restart signal must have a transition of logical
level 0 -> 1 ->0. The time they stay at high logical level (t) must be at least 200 ms.
Restart signal CH2
Dt
Activation delay. Less than 50 ms.
Diff
Less than 100 ms. If the value is greater than 100 ms, the system maintains the outputs
deactivated.
SBV System Series | Instruction manual v1.2 DEC 2021| SAF-UM-SBVBus-en-v1.2 | © 2021 Inxpect SpA
Description
8. Technical references
97