Detection exit
7.3 INFO events
7.3.1 System Boot
Every time the system is powered up, the event is logged reporting the incremental count of the boot from the
beginning of the life of the device.
Format: System Boot #n
Example:
0
2020/11/18 16:47:25
7.3.2 System configuration
Every time the system is configured, the event is logged reporting the incremental count of the configuration from
the beginning of the life of the device.
Format: System configuration #3
Example:
20
2020/11/18 16:47:25
7.3.3 Factory reset
Every time a factory reset is required, the event is logged.
Format: Factory reset
Example:
20
2020/11/18 16:47:25
7.3.4 Stop signal
If configured, every change of the Stop Signal is logged as ACTIVATION or DEACTIVATION.
Format: Stop signal ACTIVATION/DEACTIVATION
Example:
20
2020/11/18 16:47:25
7.3.5 Restart signal
If configured, every time the system is waiting for the restart signal or the restart signal is received, the event is
logged as WAITING or RECEIVED.
Format: Restart signal WAITING/RECEIVED
Example:
20
2020/11/18 16:47:25
7.3.6 Detection access
Every time motion is detected, a detection access is logged with additional parameters depending on the
selected verbosity level: the detection field number, the sensor which detected the motion, the detection
SBV System Series | Instruction manual v1.2 DEC 2021| SAF-UM-SBVBus-en-v1.2 | © 2021 Inxpect SpA
Detection exit (field #n)
[INFO]
CONTROL UNIT
[INFO]
CONTROL UNIT
[INFO]
CONTROL UNIT
[INFO]
CONTROL UNIT
[INFO]
CONTROL UNIT
SYSTEM BOOT #60
System configuration #3
Factory reset
Stop signal
ACTIVATION
Restart signal
RECEIVED