Inxpect SRE 100 Series SRE - Safety Radar Equipment Instruction manual v1.6 - EN Original instructions WARNING! Anyone who uses this system must read the instruction manual to ensure safety. Read and adhere to the "Safety information" chapter in its entirety before using the system for the first...
Page 2
Transferring the document on websites or other electronic systems. Copying contents without any modification and stating Inxpect SpA as copyright owner. Inxpect SpA reserves the right to make modifications or improvements to the relative documentation without prior notice. Requests for authorizations, additional copies of this manual or technical...
Page 6
The system for which the dangerous area is monitored. Monitored area Area that is monitored by Inxpect SRE 100 Series. It is composed of detection field 1 (e.g. used as alarm area) and detection field 2 (e.g. used as warning area) of all the sensors.
Page 7
This document includes all the information as Safety Manual according to IEC 61508-2/3 Annex D. Please refer in particular to "Safety parameters" on page 99 and to "System software" on page 125. The functioning and safety of the machinery to which Inxpect SRE 100 Series is connected is out of the scope of this document.
Page 8
Minor changes. Note: the firmware of the control unit can be updated through the Inxpect Safety application. The latest firmware version available contains the features described in the manual at the system level. The sensor firmware cannot be updated.
Page 10
2. Safety 2.1.5 INTENDED USE Inxpect SRE 100 Series is a human body detection system, certified SIL 2 according to IEC/EN 62061 and PL d according to EN ISO 13849-1. It performs the following safety functions: Access detection function: access of one or more persons to a hazardous area deactivates the safety outputs to stop the moving parts of the machinery.
Page 12
All updated certifications can be downloaded from https://www.inxpect.com/en/downloads. 2.2.2 CE The manufacturer, Inxpect SpA, states that Inxpect SRE 100 Series (Safety Radar Equipment) complies with the 2014/53/EU and 2006/42/EC directives. The full EU Declaration of Conformity text is available on the company's website: https://www.inxpect.com/en/downloads.
Serial number 3.1 Inxpect SRE 100 Series 3.1.1 Definition Inxpect SRE 100 Series is an active protection radar system that monitors the dangerous areas of machinery. 3.1.2 Special features Some of the special features of this protection system are the following:...
Page 14
3. Get to know Inxpect SRE 100 Series 3.1.3 Main components Inxpect SRE 100 Series is composed of a control unit and up to six sensors. The Inxpect Safety application allows system operation configuration and checks. 3.1.4 Control unit - sensor communication The sensors communicate with the control unit via CAN bus using diagnostic mechanisms in compliance with standard EN 50325-5 to guarantee SIL 2 and PL d.
Page 15
3. Get to know Inxpect SRE 100 Series 3.2 Control units 3.2.1 Interfaces The Inxpect SRE 100 Series supports different control units. The main difference among them is the connection ports, and therefore the communication interfaces available, and the presence of the microSD slot: Model Type...
Page 20
3.3.2 Input functions The function of each digital input must be programmed through the Inxpect Safety application. The available functions are the following: Stop signal: additional safety-related function, which manages a specific signal to force all the safety outputs (detection signal 1 and detection signal 2, if present) to OFF-state.
Page 21
Fieldbus controlled System recondition Restart signal + System recondition In the Inxpect Safety application in Settings > Digital Input-Output, set the digital input function to Single channel (Category 2) and then choose the input function for each channel. 3.3.4 Redundancy mode...
Page 22
An output is activated when it switches from OFF to ON-state and it is deactivated when it switches from ON to OFF-state. 3.4.2 Output functions The function of each digital output must be programmed through the Inxpect Safety application. The available functions are the following: System diagnostic signal: switches the selected output to OFF-state when a system fault is detected.
Page 23
(e.g., System diagnostic signal, Muting enable feedback signal and Restart feedback signal) WARNING! To use Inxpect SRE 100 Series for a category 3 safety system, both the channels of a safety output must be connected to the safety system. Configuring a safety system with only one channel safety output may result in serious injuries due to an output circuit fault and a failure of the machine to stop.
Page 24
3. Get to know Inxpect SRE 100 Series 3.4.6 Dual channel safety output configuration The dual channel safety output is automatically obtained by the Inxpect Safety application and it only matches the single OSSD outputs as follows: OSSD 1 with OSSD 2...
Page 26
Ethernet cable. The USB cable allows to configure the system locally, whereas the Ethernet cable allows to do it remotely. The Ethernet communication between the control unit and the Inxpect Safety application is secured by the most advanced security protocols (TLS).
Page 27
3. Get to know Inxpect SRE 100 Series Note*: Service user can be enabled/disabled by the administrator. Since only Inxpect technicians are allowed to access as Service, the Service user is protected by an activation code. 3.6.5 Main menu Page...
Page 30
For details, see "Control units" on page 15. 3.9.2 MODBUS communication enabling In the Inxpect Safety application, click on Admin > MODBUS Parameters and check that the feature is enabled (ON). Within the Ethernet network, the control unit acts like a server. The client must send requests to the IP address of the server on the MODBUS listening port (default port is 502).
Page 31
3.10 System configuration 3.10.1 System configuration The control unit parameters have their own default values that can be modified via the Inxpect Safety application (see "Configuration application parameters" on page 112). When a new configuration is saved, the system generates the configuration report.
Page 33
WARNING! Before activating one of the preset configurations through the safety Fieldbus, ensure that none of the digital inputs is configured as Dynamic configuration switch; otherwise, the Inxpect SRE 100 Series ignores all the switches made through the safety Fieldbus.
Page 35
Motion speed Inclination All these factors have been analyzed for a human body during the safety validation of Inxpect SRE 100 Series and cannot lead to a dangerous situation. These factors may occasionally influence the behavior of the system causing spurious activation of the safety function.
Page 36
4. Functioning principles 4.1.5 Interference with pacemakers or other medical devices Radiation from Inxpect SRE 100 Series does not interfere with pacemakers or other medical devices. 4.2 Detection fields 4.2.1 Introduction The field of view of each sensor can be composed of up to two detection fields. Each of the two detection fields has a dedicated detection signal.
Page 37
According to EN ISO 13849-1, the architectures of the control unit and S101A sensor are classified respectively as category 3 equivalent and category 2. Since Inxpect SRE 100 Series is composed of the control unit and sensors together, it can be classified category 2 or category 3 equivalent based on the installation configuration and layout.
Page 38
4. Functioning principles Inxpect SRE 100 Series compliance with PL d, category 2 architecture is always guaranteed, and does not require the installer to perform any additional operation. There is no parameter combination that can lead to a configuration which has a risk reduction lower than PL d, category 2.
Page 41
The machinery is prevented from restarting if people are in the dangerous area. prevention 5.1.2 Safety working modes Via the Inxpect Safety application, you can select which safety working mode each sensor will employ for each of its detection fields: Access detection and restart prevention (default): The sensor performs the access detection function when it is in normal operation (No alarm status).
Page 48
1. In the Inxpect Safety application in Settings > Restart function, select Automatic. 2. In the Inxpect Safety application, in Configuration for each detection field in use with automatic restart, select the desired Safety working mode and set the Restart timeout (or the T parameter, if present).
Page 49
Restart signal (Settings > Digital Input-Output). See the Fieldbus protocol for details. 4. In the Inxpect Safety application, in Configuration for each detection field in use with safe manual restart, select the Safety working mode among those allowed and set the Restart timeout parameter value.
Page 51
The muting function is enabled only if both logic signals of the dedicated input meet certain characteristics. Below is a graphic representation of the signal characteristics. In the Inxpect Safety application, in Settings > Digital Input-Output it is necessary to set the parameters that define the signal characteristics.
Page 52
Note: when the position is modified with respect to the saved references (i.e., when a sensor is rotated) and the anti-rotation around axes function is enabled, the Inxpect SRE 100 Series detects the tampering and sends the message within 5 s.
Page 53
(see "Checks when the anti-masking function is disabled" below). To change the sensitivity level or disable the function, in the Inxpect Safety application, click Settings and then Anti-tampering. 6.3.6 Checks when the anti-masking function is disabled When the anti-masking function is disabled, perform the following checks.
Page 54
6.4 Multi-control unit Synchronization 6.4.1 Introduction The multi-control unit synchronization function is necessary when multiple Inxpect SRE 100 Series are sharing the same area and it allows the interferences between their sensors to be removed using a time synchronization signal.
Page 55
6.4.5 Enable the multi-control unit synchronization function 1. For each control unit, in the Inxpect Safety application click Settings > Multi-control unit synchronization and assign a different Control unit channel. Note: if there are more than four control units, the control units with the same channel must have their monitored areas as far from each other as possible.
Page 57
(e.g., due to sensors of different systems installed too close to each other or problems on the CAN bus). In the Inxpect Safety application in Settings > Advanced, the following levels of robustness can be set: Standard (default)
Page 60
7.3 Dangerous area calculation 7.3.1 Introduction The dangerous area of the machinery to which Inxpect SRE 100 Series is applied must be calculated as indicated in standards ISO 13855:2010. For Inxpect SRE 100 Series the fundamental factors for calculation are height (h) and inclination (α) of the sensor (see "Sensor position"...
Page 65
7. Sensor position 7.4.6 Calculate the real detection distance The actual detection distance Dalarm is the value to be entered on the Configuration page of the Inxpect Safety application. Dalarm indicates the maximum distance between the sensor and the object to be detected.
Page 67
7. Sensor position 7.5.4 Calculate the real detection distance The actual detection distance Dalarm is the value to be entered on the Configuration page of the Inxpect Safety application. Dalarm indicates the maximum distance between the sensor and the object to be detected.
Page 69
Technical Support to receive assistance. 1. Download the application from the https://tools.inxpect.com website and install it on the computer. 2. With Microsoft Windows operating system, download and install from the same site also the driver for USB connection.
Page 73
Note: the maximum length of the CAN bus line from the control unit to the last sensor in the chain is 30 m (98.4 ft). Note: when replacing a sensor, in the Inxpect Safety application, click APPLY CHANGES to confirm the change.
Page 74
5. Set a new admin password, memorize it, and provide it only to authorized people. 6. Select the system (Inxpect SRE 100 Series) and the number of sensors. 7. Set the working frequency. If the system is installed in one of the countries with national restrictions, select the restricted band, otherwise select the full band.
Page 76
Validation test The validation procedure of the Inxpect SRE 100 Series system is reported below: 1. Identify the test positions, including those locations where the operator should normally be located during the production cycle:...
Page 77
8. Installation and use procedures 4. Check that the test acceptance criteria previously defined are fulfilled. 5. If the test acceptance criteria are not fulfilled, see "Validate the system with Inxpect Safety" on the next page. 6. Repeat steps 2, 3, and 4 for each test position.
Page 78
WARNING! When the validation function is active, the system response time is not guaranteed. The Inxpect Safety application is helpful during the safety functions validation phase and allows the actual field of view of the sensors to be checked based on their installation position.
Page 80
8.6.3 Restore factory default settings WARNING! The system is provided without any valid configuration. Therefore the system maintains the safe state at the first start-up until a valid configuration is applied through the Inxpect Safety application by clicking APPLY CHANGES.
Page 82
Machinery maintenance technician The machinery maintenance technician is a qualified person with the administrator privileges required to modify the configuration of Inxpect SRE 100 Series through the software and perform maintenance and troubleshooting. Contents This section includes the following topics: 9.1 Troubleshooting procedures...
Page 85
9.2.1 Introduction The event log recorded by the system can be downloaded from the Inxpect Safety application in a PDF file. The system saves up to 4500 events, divided in two sections. In each section the events are displayed from the most recent to the least recent.
Page 95
Generic maintenance technician The generic maintenance technician is a person qualified only to perform basic maintenance without the administrator privileges required to modify the configuration of Inxpect SRE 100 Series through the application. 10.1.1 Cleaning Keep the sensor clean and free of any work residues and conductive material to prevent masking and/or poor system operation.
Page 96
10.2.1 Machinery maintenance technician The machinery maintenance technician is a qualified person with the administrator privileges required to modify the configuration of Inxpect SRE 100 Series through the Inxpect Safety application and perform maintenance and troubleshooting. 10.2.2 Control unit firmware update 1.
Page 97
The SD Backup function can be enabled/disabled through the Inxpect Safety application, as well as the backup of the login credentials of all the users. By default, both options are disabled.
Page 125
IEC 61508-3 Annex D. Considering that Inxpect SRE 100 Series is an embedded system provided with a firmware already deployed on board, no software integration is required by the system installer or by the end user. The following paragraphs analyzes all the information required in IEC 61508-3 Annex D.
Page 126
12. Appendix 12.2 Disposal Inxpect SRE 100 Series contains electrical parts. As set forth in European Directive 2012/19/EU, do not dispose of the product with unsorted urban waste materials. It is the responsibility of the owner/distributor to dispose of these products, as well as other electrical and electronic equipment, through specific waste collection facilities indicated by the waste disposal services.