4.11.6 Checks when the anti-masking function is disabled
When the anti-masking function is disabled, perform the following checks.
Safety function
Access detection
function
Restart prevention
function
4.11.7 When to disable
The anti-masking function should be disabled under the following conditions:
(with restart prevention function) the monitored area includes moving parts that stop in different and
l
unpredictable positions,
the monitored area includes moving parts that vary their position while the sensors are in muting,
l
the sensor is positioned on a part that can be moved,
l
the presence of static objects is tolerated in the monitored area (e.g. loading/unloading area).
l
SBV System Series | Instruction manual v1.2 DEC 2021| SAF-UM-SBVBus-en-v1.2 | © 2021 Inxpect SpA
Schedule
Before each machinery restart
Each time the safety outputs are
deactivated
Action
Remove any objects that obstruct the field of view
of the sensor.
Reposition the sensor according to the initial
installation.