2. Measure continuity between the traction motor terminals U and W.
Is continuity present?
YES: Proceed to Step 3.
NO: Repair or replace faulty traction motor.
3. Measure continuity between the traction motor terminals W and V.
Is continuity present?
YES: Proceed to Cause C.
NO: Repair or replace faulty traction motor.
CAUSE C - FAULTY TRACTION CONTROLLER
PROCEDURE OR ACTION:
1. If no faults are found, replace controller. Make sure to indicate the DTC code(s) on the warranty claim to in-
clude an accurate problem description leading to controller replacement.
END POSSIBLE CAUSES
DIAGRAMS
END FAULT