Calibrate - Yale 524150797 Maintenance Manual

Metric and inch (sae) fasteners
Table of Contents

Advertisement

2200 YRM 1508
1. P (PARK/HOME POSITION
2. D (NOT USED)
3. T (TEACH/CALIBRATE)
4. C (CONFIGURE)
5. JUMPER TERMINAL (SV2)
Figure 12. Jumper Terminal (SV2)
6.
Turn the key switch to the ON position and view
the LED display.
NOTE: For truck model MPB045VG (A245) , the
configuration value shall be set until the seven
segment display reflects letter C.
7.
Press and release the S2 (turtle) switch or S3
(horn) switch to change the number displayed on
the LED to the correct value.
8.
Press and release the S (belly) switch to save the
value. A decimal will appear on the LED display
beside the number showing it has been saved.
9.
Turn the key switch to the OFF position and move
the jumper to the park (P) position.
10. Turn the key to the ON position and view the LED
to verify the correct number has been saved. The
LED will display the program setting for
approximately five seconds.

Calibrate

Refer to Figure 11 for the following instructions.
1.
Verify that the key switch is in the OFF position.
2.
Move the jumper from P (park) to T (teach). See
Figure 12.
a.
Ensure the leads from the Right Lift switch
connects to the JP10 socket and the leads
from the Right Lower switch connects to the
JP12 socket. See Figure 11.
b.
Ensure the leads from the Left Lift switch
connects to the JP14 socket and the leads
from the Left Lower switch connects to the
JP15 socket. See Figure 11.
c.
Ensure the tiller harness connects to AJ2
socket. See Figure 11.
3.
Verify that the battery is connected and turn the
key switch to the ON position. The LED will
display a symbol (see Figure 13 view A or B) to
signal that the card is in calibration mode.
a.
If LED displays as shown in Figure 13 view A,
return butterfly to neutral then press left lift
button. The LED will display as shown in
Figure 13 view B.
Control Handle
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents