Neutral Braking Tm2; Max Braking Tm2; Turtle Alarm Enable; Quick Lift Window - Yale 524150797 Maintenance Manual

Metric and inch (sae) fasteners
Table of Contents

Advertisement

ELECTRICAL SYSTEM

Neutral Braking TM2

Neutral braking occurs progressively when the throttle
is reduced toward the neutral position or when no di-
rection is selected. This This parameter is applicable
only while the truck is driven while in Advance Turtle
Mode.

Max Braking TM2

This parameter sets the rate (in seconds) at which the
vehicle slows down when full brake is applied or when
throttle is applied in the opposite direction. This pa-
rameter is applicable only while the truck is driven
while in Advance Turtle Mode.

Turtle Alarm enable

This parameter sets an alarm to indicate when the
truck has transition from turtle mode (TM1) to turtle
mode 2 (TM2). The truck will transition from TM1 to
TM2 when the truck is been driven in TM1 and turtle
button is depressed while tiller arm transition from op-
erational region A to operational region B. See Fig-
ure 9030-03-3.
A. OPERATIONAL REGION A
B. OPERATIONAL REGION B
C. OPERATIONAL REGION C
Figure 9030-03-3. Operational Regions
Check the Service Manual section in Yale Axcess Online for possible updates and check pertinent Bulletins
General Maintenance and Diagnostic Data

Quick Lift Window

This optional parameter defines the minimum amount
of time that the lift button needs to be depressed to
activate Quick Lift.

Initial Lift Interval

This optional parameter sets the period of time for
which the truck will lift upon Quick Lift command. It
shall be enough to lift up the load from the ground so
that load wheels can move freely.

Full Lift Interval

This optional parameter sets the period of time for
which the truck will lift once traction is commanded
while Quick Lift mode.

Lift Run Time

This parameter sets the maximum allowable time to
have the motor pump running upon lift command.

BDI Warning (Lift Lock) Enable

This parameter enables the truck to lock the lift func-
tion when BDI reaches a given percent

Warning BDI (Lift Lock Out Percent)

This parameter will set the battery discharge percent-
age at which the truck will lock the lift function

Battery-BDI Reset Volts

The reset voltage level is checked only once, when
KSI is first turned on. Note that the BDI Reset Percent
parameter also influences the algorithm that deter-
mines whether BDI Percentage is reset to 100%. Re-
set Volts Per Cell should always be set higher than
Full Volts Per Cell.

Battery- BDI Full Volts

The full voltage level sets the Keyswitch Voltage that
is considered to be state-of-charge; when a loaded
battery drops below this voltage, it begins to lose
charge. The BDI (battery discharge indicator) algo-
rithm continuously calculates the battery state-of-
charge whenever KSI is on.
9030-03-11