Meru Networks AP320 Installation Manual page 67

Access point and radio switch
Table of Contents

Advertisement

Ethernet
Cable
2. For extra protection against rain or moisture, apply weatherproofing tape (not
3. Ground the unit with an appropriate grounding wire (not included) by attaching it to
Caution!
ANSI/NFPA 70 and the Canadian Electrical Code, Part 1, and when applicable, the National
Electrical Safety Code, IEEE C2.
Equipment shall be properly grounded according to Chapter 8 of ANSI/NFPA 70, the
National Electrical Code (NEC) and the Cable distribution system should be grounded
(earthed) in accordance with ANSI/NFPA 70, the National Electrical Code (NEC), in
particular Section 820.93, Grounding of the Outer Conductive Shield of a Coaxial Cable.
The separate protective earthing terminal provided on this product shall be permanently
connected to earth.
Caution!
Note:
the IEEE 802.3af standard. Do not try to power the unit by connecting it directly to a
network switch that provides IEEE 802.3af PoE. Always connect the unit to the included
power injector module to maintain the warranty.
Note:
connecting multiple devices to one outlet, be sure to allow 1.5 amps for each AC power
adapter.
© 2008 Meru Networks, Inc.
Console Port
Console
PoE
Ground Wire
included) around the Ethernet connector.
the grounding screw on the unit. See above.
Equipment shall be installed in accordance with the National Electrical Code
Do not locate the power injector outdoors. The unit is for indoor use only.
The wireless Ethernet port does not support Power over Ethernet (PoE) based on
Each AC power injector requires 1.5 amps of power at 100-240 volts. When
PoE (Ethernet) Port
Installing the Access Points
Installing the OAP180
53