Scale Setting Value Selection; Zero Scale Output Value And Full Scale Output Value - Unipulse F377A Operation Manual

Digital indicator
Hide thumbs Also See for F377A:
Table of Contents

Advertisement

6 OPTION
- Taking voltage output signals
- Taking current output signals
- Resolution
Chapter
6

■Scale setting value selection

Four types of zero scale and full scale settings can be stored.
Switch with the selector button (
Scale of output of D/A converter changes accordingly when gain changes by the selection of
calibration value.
How to set
SET.

■Zero scale output value and full scale output value

- In the case of voltage output
- In the case of current output
How to set
SET.
76
Connect external equipment (2kΩ or more
load resistance) to + and - of the F377A.
Connect external equipment (350 Ω or less
load resistance) to CUR and G of the
F377A.
The D/A converter has a resolution of 1/10000 to -10 - +10V (4 - 20mA).
CAUTION
- The D/A converter is optional.
- Do not apply external voltage because it will break.
- Do not short-circuit the voltage output because a failure will occur.
Also, connecting a capacitive load may cause oscillation.
System Setting
Setting range: -99999 - 99999 (where zero set value < full scale set value)
Zero scale:
Set the indicated value for the time of output of 0V.
Full scale:
Set the indicated value for the time of output of 10V.
Zero scale:
Set the indicated value for the time of output of 4mA.
Full scale:
Set the indicated value for the time of output of 20mA.
System Setting
F377A
← Inside Outside →
F377A
← Inside Outside →
/
) to conduct scale setting.
Option Setting (D/A OUTPUT)
Option Setting (D/A OUTPUT)
External equipment
Load resistance:
2kΩ or more
F.G
External equipment
Load resistance:
350Ω or less
F.G