About Changing Of The Setting Work; Work Copy - Unipulse F377A Operation Manual

Digital indicator
Hide thumbs Also See for F377A:
Table of Contents

Advertisement

I/O terminal block
B1 or B7
COM2
B2
WORK0
B3
WORK1
B4
WORK2
B5
WORK3
*
* If Measurement Work Selection is not set to External Input,
measurement work cannot be specified by external input.
Also, if the B5 Function Selection setting is not WORK3, the B5 pin
does not function as WORK3.

■About changing of the setting work

When changing the hold or comparison set value of each work, set the Work No. with the Work
change key on the mode selection screen, and change the set value.
How to set
1) Select the setting Work on the Work setting screen.
2) Then, enter each set value in a likewise manner.
For making the settings of all Works equal, set the Work No. to "All".
The value set with "All" is set for all WORK00 - WORK15.
CAUTION
The setting work change key is not for specifying the measurement work.
Designate Measurement Work(s) with external selector signals WORK0 - WORK3.

■Work copy

Work can be copied. Press
Setting screen. Set Source(0-15) and Copy(0-15).
Data to be copied are all set values of Comparison
setting, Hold setting, and Graph setting.
CAUTION
It takes 15msec at the maximum for the changed work No.
to become effective. During this section, which work is
measured is undefined.
Also, when the work is switched, the hold and graph
functions are reset under the after-switching work
conditions irrespective of the previous operation.
on the Work
5 SETTING OF FUNCTIONS
Chapter
5
57

Advertisement

Table of Contents
loading