6 OPTION

■Equivalent circuit

-Output The signal output circuit is operated through a TTL open collector.
-Input
Chapter
6

■Signal timing

-STAB
-OVER
BCDdata
STAB
OVER
74
Vcc
+5V
Internal transistor status
Output data
Negative
0
OFF
1
ON
Vcc
+5V
CAUTION
- Do not apply external voltage to the signal input circuit.
- The external element is required to withstand Ic=10mA.
- Leakage from the external element is required to be 30μA or below.
This signal turns on at the same time as BCD data when stability is detected by Motion
Detect (MD). This signal is not output when the output data is a real time
value.("Motion Detect (MD)"on page 38)
This signal is output at the time of a sensor error or ±OVER.
0
1
0
1
F377A
Inside
Outside
Vceo=30V(max)
Ic =30mA (max)
COM
Output pin level
Positive
Output data
ON
OFF
Through logic switching (B14)
F377A
Inside
Outside
IC=
Approx.
6mA
Switch
COM
Vext
Negative
Positive
0
1
Open OFF
Short ON
Transistor
TTL open collector output
(ON when IN is HI)