■Hold auto reset
ON / OFF
How to set
SET.
→
・OFF:
・ON:
CAUTION
The sample hold with double hold OFF is controlled simply by the T/H signal
when auto reset is ON, but controlled by the SECTION signal and T/H signal
when auto reset is OFF.
1-4.
Hold Off on Digital Zero
You can select whether to maintain or release the hold condition when Digital Zero is executed.
ON / OFF
How to set
SET.
→
CAUTION
If ZT (Zero Tracking) is used with this setting ON, Hold Off is also performed
when the Digital Zero is reset.
● In the case of Hold Off On Digital Zero where the hold modes are
A: Sample hold
B: Inflection Point hold
D/Z
SECTION
T/H
H/E
HOLD A
Status Display
----(A)
Status Display
HOLD B
Status Display
INF B
Status Display
Initial value: ON
Work Setting
→
After a hold is confirmed, the next detection is not started until the T/H signal is
turned on even if the SECTION signal is turned on.
After a hold is confirmed, the next detection is started when the SECTION signal is
turned on again even if the T/H signal is not turned on.
Initial value: OFF
Exp. Setting
Exp. Hold Set.
→
When the Detection Start Condition is External Only
Sensor Input Value
Hold Value A
Hold Value B
Blink
ON
OFF
OFF
ON
OFF
Blink
ON
1 EXP. HOLD FUNCTIONS
Hold Setting
Page 1
→
Page 1
→
Digital Zero and Hold
Off
are
executed
simultaneously.
Blink
OFF
OFF
If T/H and DZ need to be
performed
each
time,
wiring can be omitted.
ON
ON
Blink
113
Chapter
1