1 EXP. HOLD FUNCTIONS
* OK is displayed each on the LCD screen as hold value A is OK, and hold value B is OK.
Chapter
1
1-2.

Sample Hold Trigger Edge Selection

You can select the input timing of the SECTION signal to perform sample hold from ON edge and
OFF edge.
However, OFF-edge operation can be performed only when a Hold Section exists.
● In the case of ON-edge operation
where the hold modes are
A: Sample hold
B: None
SECTION
T/H
H/E
HOLD A
Blink
Status Display
----(A)
OFF
Status Display
HOLD B
OFF
Status Display
----(B)
OFF
Status Display
110
- External I/O pin assignments for Double Hold
A1
COM1
A2
Out
HI-B
A3
Out
HI-A
A4
Out
OK
A5
Out
LO-A
A6
Out
LO-B
A7
COM1
A8
Out
HOLD END(H/E)
A9
Out
RUN
A10
Out
EVENT
A11
Out
SIF
A12
Out
SIF
FCN-365P024-AU/FCN-360C024-B
External I/O
Sensor Input Value Hold Value B
Hold Value A
ON
Blink
COM2
WORK0
IN
WORK1
IN
WORK2
IN
WORK3(LOCK)
IN
T/H
IN
COM2
SECTION
IN
DIGITAL ZERO
IN
GRAPH TRIG
IN
CAL0
IN
CAL1
IN
● In the case of OFF-edge operation
where the hold modes are
A: Sample hold
B: None
Sensor Input Value
Hold Value B)
SECTION
T/H
H/E
HOLD A
Blink
Status Display
----(A)
OFF
Status Display
HOLD B
OFF
Status Display
----(B)
OFF
Status Display
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
Hold Value A
ON
Blink