■RS-232C interface setting

Set the RS-232C communication conditions of the F377A.

Communication mode

Normal, Continue, Print
How to set
SET.
System Setting →
Baudrate
9600, 19200, 38400, 57600bps
How to set
SET.
System Setting →
Data bit
7bit, 8bit
How to set
SET.
System Setting →
Stop bit
1bit, 2bit
How to set
SET.
System Setting →
Parity bit
NONE, ODD, EVEN
How to set
SET.
System Setting →
Delimiter
CR, CR+LF
How to set
SET.
System Setting →
Flow control
Off, RTS/CTS
How to set
SET.
System Setting →
■Communication mode
1.Normal
Communications are carried out by commands from the host computer.
The indicated value, status and parameters can be read, and parameters can be written.
2.Continue
The indicated value and status are continuously transmitted.
3.Print
The indicated value is transmitted upon printing (when a print command is output to the SI/F).