1 EXP. HOLD FUNCTIONS
1-3.

Auto Reset Selection at the Start of Hold Detection

Chapter
As standard, hold reset is automatically performed at the start of each Hold Section. This allows simple
1
control as control can be performed by the SECTION signal alone without inputting the T/H signal.
By resetting the hold at the start of each Hold Section, the next hold detection would also be
performed when a hold value should be maintained in some cases, but as reset operation can be
selected by setting, such a hold value can always be maintained until the T/H signal is inputted.
When Hold Auto Reset is ON in Sample hold (Double hold OFF)
SECTION
T/H
H/E
When Hold Auto Reset is OFF in Sample hold (Double hold OFF)
SECTION
T/H
H/E

■Auto reset select setting

ON / OFF
How to set
SET.
When this setting is ON, the Auto Reset Select setting is displayed in the hold setting
menu to allow operation selection.
112
When Hold Auto Reset is ON in Externally specified section Hold Peak hold
SECTION
T/H
H/E
Upon turning-ON of the SECTION
signal, hold reset is performed and
detection starts
(Controlled by the T/H alone)
If the T/H signal chatters,
the point shifts from the
proper one.
(Controlled by the SECTION and T/H)
The first hold value is
maintained until T/H is
inputted.
Initial value: OFF
Exp. Setting
Control can be performed without inputting the T/H signal.
However, a hold value is maintained until the SECTION
signal turns ON.
When Hold Auto Reset is ON in Externally specified section Hold Peak hold
SECTION
T/H
H/E
When Hold Auto Reset is OFF in Externally specified section Hold Peak hold
SECTION
T/H
H/E
Exp. Hold Set.
Page 1
If
the
SECTION
signal
chatters, the point shifts from
the proper one.
The first hold value is
maintained until T/H is
inputted.