Enabling Svom Boot Watchdog Functionality - Fujitsu PRIMERGY RX2530 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2530 M1:
Table of Contents

Advertisement

To identify the cabinet number, enter the following command:
/usr/sbin/eecdcp -c oc=E204
I
<CPU#> parameters are "0" for CPU 1 and "1" for CPU 2.
Ê If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all processors:
Ê Log in as root.
Ê Enter the commands below, followed by [ENTER]:
1. /etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2. cd /etc/srvmagt
3. rm -f cehist.bin
4. /etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
Ê Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
5.2.8

Enabling SVOM boot watchdog functionality

If ServerView Operations Manager boot watchdog functionality has been
disabled for firmware upgrade purposes (see section
watchdog functionality" on page
maintenance task.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web frontend:
Configuring boot watchdog settings in the BIOS
Ê Enter the BIOS.
Ê Select the Server Mgmt menu.
Ê Under Boot Watchdog set the Action setting to Reset.
RX2530 M1
72), it has to be re-enabled to complete the
Upgrade and Maintenance Manual
Basic software procedures
"Disabling SVOM boot
89