Advanced Settings
Segmental Positioning
For precise cutting quality, it is suggested to apply "Segmental Positioning" by adjusting the x
and y distance when you are working on an extra long or large-size image to increase cutting
quality.
Follow the same steps in the 4-Point Positioning section to complete the contour line setting
and registration mark creation procedures. Adjust the size, object margin and line thickness of
your registration marks and the space between registration marks by changing X, Y distance in
the Setup-Jog Marks window and click OK.
Step 1
Press the Settings icon on the GreatCut toolbar.
GreatCut Plug-In